FS-Reflexion
FS-Reflexion is a geophysical measuring instrument to locate subterranean voids like caves, bunkers,
tunnels or basement vaults. FS-Reflexion works with a seismic vibration system. A transmitter generates
vibrations going into the ground. Depending on the type of soil they will be transmitted or damped.
If a void exists it will start to resonate in its own frequency and can be detected by a seismic
vibration transducer. FS-Reflexion can be used all around the world, no matter if there is stony
ground, loam or clay soil, in the mountains or in flat country.
FS-Reflexion includes different operating modes to record and analyse data:
- Check Mode to recognize seismic disturbances
- Scan Mode to record measurement values for a graphical representation
- Frequency-energy-graph to analyse seismic activities
- Data transfer to computer for graphical representation in 3D
The recorded measurement values can be analysed via the frequency-energy-graph.
In this diagram a high amplitude at specific frequencies indicates existing subterranean voids.
Additionally it is possible to summarize all measurement values to a 3D representation, so that
they can be analysed in the professional Visualizer 3D software. In that way voids cannot only
be represented visually, but also their size can be determined.
The following technical indications are medial values. During operation small variations are quite possible.
Control unit with seismic vibration transducer
| Dimensions (W x D x H) |
|
22 x 30 x 22 cm |
| Operating Temperature |
|
0 °C – 45 °C |
| Storage Temperature |
|
-20 °C – 60 °C |
| Power consumption (typical) |
|
approx. 12 W |
| Effective range |
|
4 – 22 Hz (via vibration transducer) |
| Processor |
|
AMD LX800, 500 MHz |
| Memory |
|
256 MB RAM, 128 MB data |
| Vibration transducer |
|
seismic, piezo system |
Transmitter
| Voltage |
|
12 VDC, internal batteries |
| Output power (maximal) |
|
150 W |
| Operating Temperature |
|
0 °C – 45 °C |
| Frequency (internal control) |
|
4 – 22 Hz |
Data transmission (USB)
| Maximum Transfer Rate |
|
19200 Baud |
Data transmission (Bluetooth)
| Frequency |
|
2.4 – 2.4835 GHz |
| Maximum Transfer Rate |
|
1 Mbps |
| Receiving Sensitivity |
|
-85 dBm |
| Maximum Range |
|
approx. 100 m |
Computer, minimum requirements
The computer is not part of the scope of delivery.
The indicated values should help you for a correct selection of a suitable computer
for analysis of your measured results.
| Interface (Data transmission) |
|
USB |
| Free disk space |
|
minimum 50 MB |
| Working memory (RAM) |
|
minimum 256 MB |
| Graphic card |
|
minimum 128 MB, OpenGL-compatible |
| Processor |
|
minimum 1.2 GHz |
| Operating system |
|